Interventional Cardiology Bare Metal Coronary Stent Manufacturing by Orthi Medical

Bare Metal Coronary Stent Solutions: Technical Procurement & Engineering Excellence

Precision Cobalt-Chromium & 316L Stainless Steel balloon-expandable stent systems engineered by Orthi Medical Co., Ltd. Ultra-thin strut geometry, minimal recoil, and ISO 13485 certified OEM capabilities for global B2B healthcare buyers.

Advanced Cleanroom Laser Cutting for Cardiovascular Stents

Engineered for Rapid Endothelialization

Advanced thin-strut designs optimized for High Bleeding Risk (HBR) patients, short DAPT regimens, and cost-effective interventional cardiology procedures worldwide.

0 μm Ultra-Thin Strut Profile (CoCr)
< 3.2% Minimal Elastic Recoil Rate
ISO 13485 CE & GMP Compliant Facility
100% Custom OEM / ODM & Private Labeling
Orthi Medical ISO Class 7 Cleanroom Stent Manufacturing Facility
Play Video
Watch: Cleanroom Stent Production & Quality Control
Search Intent & Clinical Analysis

Why the Bare Metal Coronary Stent (BMS) Retains a Vital Role in Modern Percutaneous Coronary Intervention (PCI)

In an era dominated by drug-eluting stents (DES), interventional cardiologists, cath lab procurement directors, and international medical device importers frequently question the ongoing market demand for Bare Metal Coronary Stents (BMS). Clinical evidence and health-economic data demonstrate that high-performance BMS platforms engineered by Orthi Medical Co., Ltd. fulfill critical niches where DES technologies present clinical risks or economic inefficiencies.

  • High Bleeding Risk (HBR) Protocol Optimization: BMS implantation requires only 1 month of Dual Antiplatelet Therapy (DAPT), mitigating life-threatening hemorrhage in elderly, frail, or coagulopathic patients compared to prolonged DES DAPT requirements.
  • Accelerated Functional Endothelialization: Uncoated Cobalt-Chromium (CoCr L605) and 316L Stainless Steel struts promote rapid biological healing, complete arterial re-endothelialization within 30 days, and complete elimination of polymer-induced chronic vessel inflammation.
  • Urgent Non-Cardiac Surgery Candidates: Patients requiring immediate surgical interventions (such as orthopedic trauma, oncological resections, or vascular repairs) cannot safely defer surgery for 6 to 12 months under DES DAPT regimens. BMS allows safe procedure scheduling after 30 days.
  • Economic Value for National Healthcare Systems: BMS remains the gold-standard workhorse in high-volume, cost-sensitive markets, offering high vessel scaffolding efficiency without drug/polymer licensing premiums.
Get a Quote
Cardiovascular Portfolio

Orthi Medical Bare Metal Coronary Stent Systems & Accessories

Engineered to deliver exceptional deliverability, vessel conformability, and reliable radial scaffolding. Supplied fully crimped on high-pressure balloon delivery catheters in sterile Tyvek packaging.

Bare Metal Coronary Stent System Cobalt Chromium by Orthi Medical
Flagship Cardiovascular Stent

Orthi-Cor™ CoCr Bare Metal Coronary Stent

Engineered from medical-grade Cobalt-Chromium L605 alloy (ASTM F90). Features 60–75 μm ultra-thin struts, an open-cell sine-wave geometry, excellent radiopacity, and an entry profile as low as 0.016 inches for complex vessel crossability.

Non Compliant High Pressure Balloon Dilatation Catheter
Post-Dilatation Catheter

NC High-Pressure Balloon Dilatation Catheter

Designed for pre-dilatation and post-stent expansion optimization. Features a non-compliant PEBAX balloon material with a Rated Burst Pressure (RBP) up to 20 atm, ensuring homogeneous stent wall apposition without dog-boning.

Double J Ureteral Stent Pigtail Catheter Medical Device
Urological Stent Systems

Double J Ureteral Stent Catheter

Biocompatible polyurethane urological stent featuring smooth hydrophilic coating, tapered tip design, and radiopaque longitudinal marker line for accurate endourology positioning and drainage.

OEM ODM Precision Micro Machining Implants by Orthi Medical
OEM / ODM Custom Manufacturing

OEM Stent Strut & Micro-Tubing Laser Cutting

Custom OEM laser-cutting of CoCr L605, Nitinol, and 316L SS micro-tubing. Precision femtosecond laser cutting, chemical etching, electropolishing, and cleanroom crimping tailored to customer specifications.

Engineering Specifications

Orthi-Cor™ Bare Metal Coronary Stent System Engineering Data

Rigorous mechanical testing per ASTM F2078, ASTM F2477, and ISO 25539-2 ensures exceptional structural integrity, pushability, trackability, and radial resistance.

Orthi-Cor Bare Metal Coronary Stent Technical Specifications
Technical Parameter Cobalt-Chromium (CoCr L605) Specification 316L Stainless Steel Specification
Strut Thickness 60 μm (Small Vessel) / 75 μm (Large Vessel) 80 μm – 85 μm
Stent Material Standard ASTM F90 / ISO 5832-5 ASTM F138 / ISO 5832-1
Nominal Expansion Diameters 2.0 mm, 2.25 mm, 2.5 mm, 2.75 mm, 3.0 mm, 3.5 mm, 4.0 mm, 4.5 mm 2.5 mm, 3.0 mm, 3.5 mm, 4.0 mm, 5.0 mm
Stent Length Matrix 8 mm, 12 mm, 15 mm, 18 mm, 23 mm, 28 mm, 33 mm, 38 mm 9 mm, 13 mm, 16 mm, 19 mm, 24 mm, 29 mm, 34 mm
Elastic Recoil Rate < 3.2% (deflated at nominal pressure) < 3.8% (deflated at nominal pressure)
Longitudinal Foreshortening < 2.5% at maximum expansion diameter < 3.0% at maximum expansion diameter
Radial Strength (Collapse Pressure) > 1.6 bar (> 1200 mmHg) > 1.4 bar (> 1050 mmHg)
Delivery Catheter Compatibility 0.014" Guidewire / 5F & 6F Guiding Catheter 0.014" Guidewire / 6F Guiding Catheter
Balloon Marker Bands Twin Swaged Platinum-Iridium (Pt/Ir) Markers Twin Swaged Platinum-Iridium (Pt/Ir) Markers
Sterilization Assurance Level EtO Sterilization, SAL 10-6 (ISO 11135 compliant) EtO Sterilization, SAL 10-6 (ISO 11135 compliant)
Enterprise Advantages & E-E-A-T Quality Assurance

Manufacturing Integrity & Quality Systems at Orthi Medical Co., Ltd.

At Orthi Medical Co., Ltd., every coronary stent system undergoes comprehensive structural, dimensional, and metallurgical validation before release. Operating under rigorous ISO 13485 and ISO 9001 certified quality management systems, our cleanroom manufacturing facility integrates state-of-the-art optical inspection, mechanical testing labs, and sterile barrier assembly lines.

ISO 13485Medical Device QMS
ISO 9001Quality Assurance
CE MarkEuropean Compliance
Raw Material Standards for Orthi Medical Cardiovascular Devices
Raw MaterialStandard SpecificationTensile / Mechanical Performance
Cobalt-Chromium L605ASTM F90 / ISO 5832-5Tensile Strength ≥ 1000 MPa, High Ductility
316L Stainless SteelASTM F138 / ISO 5832-1High Radial Force, Excellent Purity
Pt/Ir Marker AlloyASTM B68890/10 Platinum-Iridium High Radiopacity
Get a Quote
Orthi Medical ISO 13485 Quality System Certificate
Clinical Expertise & Global Support

Surgeon Training, Clinical Protocols & Technical Support

Orthi Medical Co., Ltd. supports healthcare providers and international partners with complete technical documentation, bench test validation data, and cath lab training materials.

Interventional Cardiology Symposium and Technical Workshop

Bench Testing Dossiers

Comprehensive fatigue test reports (> 400 million stress cycles per ASTM F2477), kink resistance, and recoil evaluation files.

Cath Lab Technique Guides

Step-by-step sizing, prep, trackability maneuver, and inflation pressure guides for interventional specialists.

Regulatory Documentation

CE MDR aligned technical files, ISO 11135 sterilization validation, and biocompatibility studies per ISO 10993.

OEM Engineering Consultation

Direct collaboration with our senior biomedical engineers for custom strut geometry, crimping, and packaging OEM designs.

Clinical Voices & Industry Evaluations

What Interventional Specialists & Procurement Directors Say

Interventional Cardiology Specialist
"Orthi Medical’s Cobalt-Chromium Bare Metal Stent displays outstanding pushability and crossability even through calcified, tortuous coronary arteries. The mechanical radial stability and predictable low recoil make it a trusted choice for high bleeding risk cases requiring short DAPT protocols."
Dr. M. Al-Mansoor, MD Chief of Interventional Cardiology, Regional Medical Center
Medical Device Procurement Director
"Partnering with Orthi Medical Co., Ltd. for our OEM coronary stent line streamlined our regulatory approval process. Their ISO 13485 cleanroom capabilities, flawless laser polishing, and consistent lead times have made them an essential partner in our global expansion."
E. Weber Global Procurement Director, Cardiovascular Solutions Group
B2B Procurement & Technical FAQ

Frequently Asked Questions by Global Medical Buyers & Distributors

Key questions answered regarding clinical indications, metallurgical standards, OEM capabilities, compliance documentation, and bulk procurement protocols.

Ask an Engineer →
What clinical indications make Bare Metal Coronary Stents (BMS) preferable over Drug-Eluting Stents (DES)?
Bare Metal Stents remain clinically essential for patients with High Bleeding Risk (HBR) who cannot tolerate prolonged Dual Antiplatelet Therapy (DAPT), individuals requiring urgent elective non-cardiac surgery within 30 days of stenting, non-compliant patient cohorts, and economic healthcare purchasing programs prioritizing rapid endothelialization without persistent polymer hypersensitivity.
What metallurgical standards are used in Orthi Medical BMS manufacturing?
Orthi Medical Co., Ltd. manufactures bare metal stents using medical-grade Cobalt-Chromium L605 alloy (ASTM F90) and 316L Stainless Steel (ASTM F138). These alloys enable ultra-thin strut geometry (60 to 75 micrometers), outstanding radiopacity under fluoroscopy, and high radial strength with minimal elastic recoil.
What is the elastic recoil and foreshortening performance of your coronary stents?
Our Cobalt-Chromium bare metal coronary stent systems demonstrate less than 3.2% elastic recoil upon balloon deflation and under 2.5% longitudinal foreshortening during maximum expansion, ensuring precise placement across target lesions and minimal shear stress on healthy vessel walls.
Does Orthi Medical Co., Ltd. offer OEM, ODM, and unmounted stent supply?
Yes. We provide complete OEM/ODM solutions, including custom micro-laser tube cutting, femtosecond electropolishing, stent crimping onto customer-specified balloon catheters, private label sterile Tyvek packaging, and technical dossier compilation for local regulatory approvals.
What sterilization methods and shelf life certifications apply to Orthi Medical coronary stents?
All finished stent systems are sterilized using validated Ethylene Oxide (EtO) processes to achieve a Sterility Assurance Level (SAL) of 10-6 in compliance with ISO 11135, supported by real-time and accelerated stability testing establishing a 3-year to 5-year shelf life.
Technical Insights & Market Whitepapers

Cardiovascular & Interventional Device Articles

Expert perspectives on stent design, material metallurgy, and regulatory registration strategies.

Bare Metal Stent Strut Geometry and Hemodynamics
Biomedical Engineering

Strut Geometry Impact on Arterial Endothelialization

How reducing Cobalt-Chromium strut thickness from 100 μm to 60 μm alters wall shear stress and accelerates 30-day arterial healing.

DAPT Regimens and HBR Patient Care
Clinical Cardiology

Managing High Bleeding Risk (HBR) in Modern PCI

Evaluating 1-month DAPT outcomes in high-bleeding-risk patients using ultra-thin bare metal stent platforms.

OEM GUIDELINES
Regulatory Compliance

Navigating ISO 25539-2 Compliance for Stents

A step-by-step B2B guide for international medical distributors registering vascular stents under European CE MDR and FDA guidelines.

Expand Your Cardiovascular Device Portfolio Today

Partner with Orthi Medical Co., Ltd. for premium Bare Metal Coronary Stents, OEM laser-cutting, or high-pressure balloon catheters. Contact our technical team at for instant specifications and factory direct pricing.

Get a Quote